Every room has
a different problem.
Click any room type to see the full wall assembly, layer by layer, with STC contribution of each material.
Wall Assembly Cross-Section
STC Contribution by Layer
Woodside, CA — 2024. Client: Marcus Webb, producer. Drum kit in basement, studio above.
Wall Assembly Cross-Section
STC Contribution by Layer
Marin County, CA — 2025. Client: Priya Nair, architect. 700 sq ft dedicated theater room.
Wall Assembly Cross-Section
STC Contribution by Layer
Oakland, CA — 2025. Client: The Okonkwo family. Party wall adjacent to shared stairwell and neighbor TV.
Wall Assembly Cross-Section
STC Contribution by Layer
San Francisco, CA — 2025. Developer: Anchor Pacific Group. 24-unit residential condo, all party walls.
Five materials.
Each earns its STC points.
Soundproofing is a system, not a product. Remove any layer and the rating drops. Every material has a job.
Mass-Loaded Vinyl
MLVThe limp mass principle. Heavy, flexible barrier that converts sound energy to heat. 1–2 lb/ft². No air pockets.
Resilient Channel
RCThe decoupler. Screws into the stud; drywall screws into the channel — never into the stud. This break in the structure path is where most isolation happens.
The gap between these is where +14 STC lives.
Acoustic Mineral Wool
RockwoolDenser than fiberglass. Targets the 125–500Hz range where bass and vocal bleed live. Safe'n'Sound 3.5" fills the stud cavity completely.
Double-Layer Type X
Type X5/8" fire-rated drywall, applied in two layers with offset joints. The mass layer. No shared seams means no flanking path through the board boundary.
Green Glue Compound
Green GlueViscoelastic damping compound applied between drywall layers. Converts mechanical vibration to heat at the board interface. Effective from 250Hz–4kHz.
STC is logarithmic. The difference between STC 40 and STC 50 isn't a 25% improvement — it's a perceived halving of noise. Going from STC 21 to STC 63 means the sound arriving on the other side has lost over 99% of its energy.
Numbers don't lie.
Decibel meters don't either.
“I had a drum kit in the basement and a lease renewal conversation every month. After Deaden, my upstairs neighbor asked if I'd stopped playing. I hadn't. STC 67. Measured.”

“I specify Deaden on every project where I need documented STC compliance. They give me the test data, the assembly drawings, and the contractor never calls me with questions. That's rare.”

“I could hear my HVAC in every take. The recordings sounded like they were made in a hallway. Now the room is dead. That's the only word for it. Dead. Exactly what I needed.”
See Your Wall Build.
Tell us your room, your noise source, and your target. We'll send you the exact assembly spec, layer count, and a ballpark cost — before you call.